This method is applicable to wastewater containing ammonia nitrogen within the range of 0–300 mg/L. Excessive calcium and magnesium ions, residual chlorine, turbidity, or other interfering factors may affect measurement accuracy.
| Measurement Method | Salicylic Acid Spectrophotometric Method |
|---|---|
| Measurement Range | 0–300 mg/L |
| Indication Error | ≤ ±3% when ≥ 5.00 mg/L; ≤ ±5% when < 5.00 mg/L |
| Repeatability | ≤ ±2% |
| Measurement Cycle | Minimum cycle is 20 minutes; color development time can be adjusted flexibly between 5–30 min based on environmental conditions. |
| Sampling Cycle | Adjustable time interval (10–9999 min) or on-the-hour measurement mode. |
| Calibration Cycle | Adjustable at any interval from 1–99 days. |
| Maintenance Cycle | ≥ 168 hours, with each maintenance lasting approximately 1 hour. |
| Reagent Consumption | < 0.50 CNY per sample. |
| Outputs | RS-232, 4–20 mA, RS-485 |
| Environmental Requirements | Temperature-controlled indoor environment (recommended: 5–40 °C); humidity 45%–85%. |
| Power Supply | AC 220 ± 10% V, 50 ± 1% Hz, 5 A |
| Dimensions | Height 1500 × Width 500 × Depth 450 mm |
Unique Design: This product features a distinctive design that ensures lower failure rates, reduced maintenance requirements, minimal reagent consumption, and higher cost-effectiveness compared to similar products.
Enables flexible reagent sampling timing and diverse channel configurations. Minimizes dead volume for easy maintenance and extended service life.
Utilizes a visual photoelectric system for precise reagent measurement, eliminating quantitative errors caused by peristaltic pump tube wear. Achieves accurate micro-dosing with 0.7 mL per dose, significantly reducing reagent usage.
Employs a peristaltic pump with negative pressure suction, creating an air buffer zone between reagents and the pump tube to prevent corrosion. Simplifies and enhances flexibility in reagent mixing.
Operates under high-temperature and high-pressure conditions to accelerate reactions. Eliminates corrosion risks from volatile gases in open systems.
Uses imported modified PTFE (polytetrafluoroethylene) transparent tubing with an inner diameter > 1.5 mm to minimize clogging by particulate matter in water samples.
After the water sample is mixed with a masking agent, ammonia nitrogen (present as free ammonia or ammonium ions) reacts with a salicylic acid chromogenic reagent under alkaline conditions and in the presence of a sensitizing agent, forming a colored complex. The analyzer detects this color change, converts it into an ammonia nitrogen concentration value, and outputs the result. The amount of colored complex formed corresponds to the concentration of ammonia nitrogen.