Online Water Quality Monitor
Created with Pixso.

Total Nitrogen Analyzer TN Online Water Quality Analyzer with Potassium Persulfate Resorcinol Spectrophotometric Method 0-300mg/L Range RS-232 4-20mA RS-485 Output

Total Nitrogen Analyzer TN Online Water Quality Analyzer with Potassium Persulfate Resorcinol Spectrophotometric Method 0-300mg/L Range RS-232 4-20mA RS-485 Output

Brand Name: JUGE
Model Number: AG-TN07
MOQ: 1 Unit
Price: USD2000-7000
Packaging Details: Neutral carton
Payment Terms: Online order,T/T
Detail Information
Place of Origin:
Nanjing, China
Certification:
IOS9001, CE
Type:
Total Nitrogen
Principle:
Potassium Persulfate Resorcinol Spectrophotometric Method
Range:
0-300mg/L OEM
Accuracy:
≤±10%
Repeatability:
≤±5%
Measurement Period:
30min
Output:
RS-232, 4-20mA, RS-485
Specification:
1500*500*450mm
Supply Ability:
100 Unit/Week
Highlight:

Potassium Persulfate Resorcinol Total Nitrogen Analyzer

,

0-300mg/L Range TN Online Water Quality Analyzer

,

RS-232 4-20mA RS-485 Output Total Nitrogen Monitor

Product Description
Application

This method is applicable to wastewater with total nitrogen concentrations within the range of 0–300 mg/L.

Technical Parameters
Parameter Specification
Measurement Method Potassium persulfate resorcinol spectrophotometric method
Measurement Range 0–300 mg/L
Accuracy ≤ ±10%
Repeatability ≤ ±5%
Measurement Cycle Minimum cycle is 45 minutes; color development time can be adjusted flexibly between 5–30 min based on environmental conditions
Sampling Cycle Adjustable time interval (10–9999 min) or on-the-hour measurement mode
Calibration Cycle Adjustable at any interval from 1–99 days
Maintenance Cycle ≥ 168 hours, with each maintenance lasting approximately 1 hour
Reagent Consumption < 0.50 CNY per sample
Outputs RS-232, 4–20 mA, RS-485
Environmental Requirements Temperature-controlled indoor environment (recommended: 5–40°C); humidity 45%–85%
Power Supply AC 220 ±10% V, 50 ±1% Hz, 5A
Dimensions Height 1500 × Width 500 × Depth 450 mm
Additional Features
  • Data retention during abnormal alarms or power outages.
  • Touchscreen display and command input.
  • Automatic discharge of residual reactants and resumption of operation after power restoration or system reset.
Key Features

Unique Design: This product features a distinctive design that ensures lower failure rates, reduced maintenance requirements, minimal reagent consumption, and higher cost-effectiveness compared to similar products.

1. Selector Valve Assembly
  • Enables flexible reagent sampling timing and diverse channel configurations.
  • Minimizes dead volume for easy maintenance and extended service life.
2. Micro-Dosing Unit
  • Utilizes a visual photoelectric system for precise reagent measurement, eliminating quantitative errors caused by peristaltic pump tube wear.
  • Achieves accurate micro-dosing with 0.7 mL per dose, significantly reducing reagent usage.
3. Sample Introduction Unit
  • Employs a peristaltic pump with negative pressure suction, creating an air buffer zone between reagents and the pump tube to prevent corrosion.
  • Simplifies and enhances flexibility in reagent mixing.
4. Sealed Digestion Unit
  • Operates under high-temperature and high-pressure conditions to accelerate reactions.
  • Eliminates corrosion risks from volatile gases in open systems.
5. Reagent Tubing
  • Uses imported modified PTFE (polytetrafluoroethylene) transparent tubing with an inner diameter >1.5 mm to minimize clogging by particulate matter in water samples.
Analytical Principle

In the presence of potassium persulfate, nitrogen-containing compounds in the water sample are completely converted to nitrate nitrogen after high-temperature digestion. Under acidic conditions, the nitrate nitrogen reacts with an indicator reagent to form a colored complex. The analyzer detects this color change, converts it into a total nitrogen concentration value, and outputs the result. The amount of colored complex generated corresponds to the total nitrogen concentration.