For water-quality monitoring, aquaculture and hydroponic projects, pH is a central indicator of environmental health. For electronics hobbyists and developers, building a reliable Arduino-based pH measurement system raises questions about hardware, calibration and maintenance. The Gravity laboratory-grade analog pH sensor kit offers a standardized hardware approach to such chemical measurement experiments.
A pH sensor is an electrochemical tool that measures hydrogen ion concentration in solution. The Gravity kit comprises three core components: a BNC-interface probe, a signal conversion board and an analog connecting cable. The kit converts the electrode signal into an analog voltage that an Arduino can read, with a measurement range of 0 to 14 pH and accuracy of ±0.1 pH at 25°C.
The probe connects to the board through a BNC connector, while the board links to the microcontroller through a PH2.0 interface. Stable 5.00V power is required for consistent readings.
| Parameter | Specification |
|---|---|
| Measurement range | 0–14 pH |
| Accuracy | ±0.1 pH (25°C) |
| Connector | BNC (probe) / PH2.0 (board) |
| Power supply | 5.00V stable supply |
Accurate measurement depends on both hardware connection and software calibration. The board has an onboard gain-adjustment potentiometer. Connected to an Arduino analog input pin, it can be calibrated in code so that voltage values are converted into pH values. The kit is designed primarily for intermittent laboratory measurement and is not intended for continuous immersion in test liquids, which can cause the probe to drift.
Users must supply their own standard buffer solutions, because the kit does not include them. Calibration should match the expected pH range of the target samples. Probe storage also requires attention: the probe must not be allowed to dry out and should be kept in KCl 3N solution.
The combination of stable power, correct calibration and proper storage is essential for reproducible results. Readings should be checked against fresh buffer solutions at intervals appropriate to the experimental conditions.
For water-quality monitoring, aquaculture and hydroponic projects, pH is a central indicator of environmental health. For electronics hobbyists and developers, building a reliable Arduino-based pH measurement system raises questions about hardware, calibration and maintenance. The Gravity laboratory-grade analog pH sensor kit offers a standardized hardware approach to such chemical measurement experiments.
A pH sensor is an electrochemical tool that measures hydrogen ion concentration in solution. The Gravity kit comprises three core components: a BNC-interface probe, a signal conversion board and an analog connecting cable. The kit converts the electrode signal into an analog voltage that an Arduino can read, with a measurement range of 0 to 14 pH and accuracy of ±0.1 pH at 25°C.
The probe connects to the board through a BNC connector, while the board links to the microcontroller through a PH2.0 interface. Stable 5.00V power is required for consistent readings.
| Parameter | Specification |
|---|---|
| Measurement range | 0–14 pH |
| Accuracy | ±0.1 pH (25°C) |
| Connector | BNC (probe) / PH2.0 (board) |
| Power supply | 5.00V stable supply |
Accurate measurement depends on both hardware connection and software calibration. The board has an onboard gain-adjustment potentiometer. Connected to an Arduino analog input pin, it can be calibrated in code so that voltage values are converted into pH values. The kit is designed primarily for intermittent laboratory measurement and is not intended for continuous immersion in test liquids, which can cause the probe to drift.
Users must supply their own standard buffer solutions, because the kit does not include them. Calibration should match the expected pH range of the target samples. Probe storage also requires attention: the probe must not be allowed to dry out and should be kept in KCl 3N solution.
The combination of stable power, correct calibration and proper storage is essential for reproducible results. Readings should be checked against fresh buffer solutions at intervals appropriate to the experimental conditions.