A portable chemical oxygen demand (COD) analyzer uses 254 nm spectral absorption to deliver rapid on-site estimates of organic pollution, offering an alternative to conventional laboratory testing that can be time-consuming and reagent-intensive. The device is designed for field water-quality assessment, where speed, portability and durability matter. By measuring how dissolved organic matter absorbs ultraviolet light, it estimates COD and biochemical oxygen demand (BOD) levels without chemical reagents.
The analyzer relies on the 254 nm spectral absorption coefficient (SAC254) to detect the ultraviolet absorption characteristics of dissolved organic matter in water. That optical measurement is used to produce rapid estimates of COD and BOD.
Because the method does not require chemical reagents, it reduces the burden of handling and disposing of chemical waste, a common task for laboratories running conventional COD tests. The approach also shortens the interval between sampling and result, supporting real-time analysis in the field.
The device is packaged for outdoor use, with a protection rating and data handling features intended to support sustained field work. Its core specifications are summarized below.
| Feature | Technical specification / description |
|---|---|
| Measurement principle | 254 nm spectral absorption coefficient (SAC254) |
| Protection rating | IP67, suited to harsh outdoor environments |
| Display interface | 3.5-inch color screen with an intuitive menu design |
| Data storage | 8 GB internal storage with USB data export |
| Power supply | Built-in rechargeable battery with USB charging |
The analyzer has a curved body and a rubber anti-slip hand strap, features intended to keep the device secure in wet or poor weather conditions. Automatic sensor recognition and an adaptive reading interface are designed to reduce setup steps when sensors are changed.
Those features are aimed at environmental monitoring staff who need to operate equipment in complex field environments. The design emphasis is on stable handling and efficient workflow rather than laboratory-style procedures.
The instrument is suited to a range of water-quality assessment tasks that benefit from portable, real-time monitoring. Its described applications include:
In these settings, the device is intended to provide immediate field estimates that can inform further sampling or operational decisions; conventional laboratory methods remain the reference for regulatory compliance.
A portable chemical oxygen demand (COD) analyzer uses 254 nm spectral absorption to deliver rapid on-site estimates of organic pollution, offering an alternative to conventional laboratory testing that can be time-consuming and reagent-intensive. The device is designed for field water-quality assessment, where speed, portability and durability matter. By measuring how dissolved organic matter absorbs ultraviolet light, it estimates COD and biochemical oxygen demand (BOD) levels without chemical reagents.
The analyzer relies on the 254 nm spectral absorption coefficient (SAC254) to detect the ultraviolet absorption characteristics of dissolved organic matter in water. That optical measurement is used to produce rapid estimates of COD and BOD.
Because the method does not require chemical reagents, it reduces the burden of handling and disposing of chemical waste, a common task for laboratories running conventional COD tests. The approach also shortens the interval between sampling and result, supporting real-time analysis in the field.
The device is packaged for outdoor use, with a protection rating and data handling features intended to support sustained field work. Its core specifications are summarized below.
| Feature | Technical specification / description |
|---|---|
| Measurement principle | 254 nm spectral absorption coefficient (SAC254) |
| Protection rating | IP67, suited to harsh outdoor environments |
| Display interface | 3.5-inch color screen with an intuitive menu design |
| Data storage | 8 GB internal storage with USB data export |
| Power supply | Built-in rechargeable battery with USB charging |
The analyzer has a curved body and a rubber anti-slip hand strap, features intended to keep the device secure in wet or poor weather conditions. Automatic sensor recognition and an adaptive reading interface are designed to reduce setup steps when sensors are changed.
Those features are aimed at environmental monitoring staff who need to operate equipment in complex field environments. The design emphasis is on stable handling and efficient workflow rather than laboratory-style procedures.
The instrument is suited to a range of water-quality assessment tasks that benefit from portable, real-time monitoring. Its described applications include:
In these settings, the device is intended to provide immediate field estimates that can inform further sampling or operational decisions; conventional laboratory methods remain the reference for regulatory compliance.